Blink Reflex Device Objectively Identifies Concussion

By HospiMedica International staff writers
Posted on 28 Feb 2018
A new study suggests that measuring blink reflex parameters my offer a reliable tool for identifying concussion head injuries and other neurological disorders.

Developed at The Military College of South Carolina (The Citadel; Charleston, SC, USA) and the Medical University of South Carolina (MUSC; Charleston, USA), the Blink Reflexometer is a high-speed videography-based device that triggers, records, and analyzes detailed information on a person's blink reflex. More...
The person being evaluated wears a mask that delivers three to five air puffs at random intervals over 20 seconds to the outer corner of the right or left eye (randomly selected).

After approximately 20 seconds of rest, two more sets of puffs are delivered to complete the session, for a total of 6 to 12 puffs per session. The blink reflex is recorded at 280 frames/second and specific frames are then isolated and analyzed. To validate the device, the researchers collected blink reflex data from 24 male football players (18-22 years of age) over the 2015-2016 athletic seasons. Preseason baseline values were established for ten blink reflex parameters, athletic history, physical examination, balance parameters, and neurocognitive test scores.

Participants were divided into two sub-groups based on whether a concussive event was suspected. The results showed that control athletes had significantly increased blink latency, decreased differential latency, decreased lid velocity, longer time to open, fewer oscillations, and shorter total blink duration. Athletes who had suffered a head impact showed decreased blink latency, increased differential latency, decreased log of time to open, and increased log of number of oscillations compared to their baseline values. The study was published on January 22, 2018, in Biomedical Engineering.

“A human's blink reflex has a long pathway, originating at the facial area and continuing to the brain stem. If any place along that pathway is damaged, changes in the blink reflex can indicate that there is a potential problem,” said lead author Professor Dena Garner, PhD, of The Citadel. “We now know that concussions and normal play both affect the blink parameters, but in differing directions. Our observations identified something distinctly different occurring in the concussion brains that can serve as a valuable new indicator for diagnosing the condition.”

The blink reflex is a primitive brainstem response to an external stimulus, such as air, visual cues, or electrical signals, which is affected by multiple neurological disorders, including those that affect the dopaminergic circuit that controls the eyelid. Previous studies using electromyography (EMG) have shown that diffuse axonal injury and exercise result in measurable changes in the blink reflex.

Related Links:
The Military College of South Carolina
Medical University of South Carolina


Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Creatinine/eGFR Meter
StatSensor® Creatinine/eGFR Meter
Blood Pressure Monitor
Cuff Blood Pressure Monitor
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Surgical Techniques

view channel
Image Credit: 123RF

Needle-Free Intrauterine Anesthesia Technique Reduces Pain During IUD Insertion

Pain during intrauterine device (IUD) placement often deters women from choosing this long-acting contraception. Avoiding or undertreating procedural pain can reduce uptake and satisfaction with effective... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.