Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Biometric Toilet Seat Detects Congestive Heart Failure

By HospiMedica International staff writers
Posted on 01 Apr 2019
A toilet-seat based cardiovascular monitoring system can help lower hospital readmission rates for patients with congestive heart failure (CHF).

A product of Heart Health Intelligence (HHI; Rochester, NY, USA), the system integrates an electrocardiogram (ECG), ballistocardiogram (BCG), and photoplethysmogram (PPG) into a toilet seat capable of clinical-grade measurements of patient weight, pulse rate, systolic and diastolic blood pressure, stroke volume, and peripheral blood oxygenation. More...
Software algorithms then analyze the data, alerting medical providers of a deteriorating condition. A report is also passed to hospital cardiologists, who can then determine if intervention is necessary.

The system installs directly on a standard toilet, is battery powered, wireless, waterproof, and requires no additional connections or user interaction, unobtrusively capturing cardiovascular data automatically whenever the user sits on the toilet. The seat incorporates a single-lead ECG for measuring the electrical activity of the heart and as a reference for ensemble averaging, a BCG for measuring the mechanical forces associated with the cardiac cycle, and a PPG for measuring SpO2 and pulse transit time (PTT). A floating hinge ensures that the weight on the seat is completely captured by the load cells, rather than having a portion of it carried by the hinge.

In a study that compared the toilet seat–based estimates of blood pressure and peripheral blood oxygenation to a hospital-grade vital signs monitor in 18 subjects over an eight-week period, clinical grade accuracy was achieved for all of measurements. Accuracy of diastolic and systolic blood pressure was 1.2 mm and –2.7 mm Hg, respectively. Stroke volume had an accuracy of –2.5 mL, compared to the gold standard, an echocardiogram (ECG). Peripheral blood oxygenation had an error of 2.3%. The study was published in the January 2019 issue of JMIR mHealth and uHealth.

“Typically, within 30 days of hospital discharge, 25% of patients with CHF are readmitted; after 90 days of hospital discharge, 45% of patients are readmitted,” said Nicholas Conn, PhD, founder and CEO of HHI and a researcher at the Rochester Institute of Technology (RIT; NY, USA). “The penalty alone for readmitting 150 patients is approximately USD 500,000 annually. The total cost of providing 150 patients with their own monitored toilet seats from HHI is USD 200,000. Hospital systems will save more than double their initial investment within one year.”

The U.S. Hospital Readmission Reduction Program (HRRP) was introduced by Medicare in order to improve patient care by penalizing hospitals with poor outcomes. One key outcome measure is the readmission rate; in 2013 Medicare levied fines of USD 227 million in fines against 2,225 hospitals that will have their payments reduced by up to 2% for a year. The penalties are based on readmissions of Medicare patients who originally went into the hospital with at least one of three conditions - heart attack, heart failure, and pneumonia.

Related Links:
Heart Health Intelligence
Rochester Institute of Technology


Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Patient Monitoring System
AlarmSense
Fetal Monitor
BT-380
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Surgical Techniques

view channel
Image: The thin foetoscope is guided through the abdominal wall to the placenta. Small magnets in its tip react to an externally generated magnetic field, enabling the instrument to be bent with precision. The robotic platform is designed to occlude shared blood vessels in the placenta of twins with twin-to-twin transfusion syndrome. (Image Credit: created with BioRender.com, ETH Zurich)

Robotic Platform Advances Fetoscopic Treatment of Twin-to-Twin Transfusion Syndrome

Twin-to-twin transfusion syndrome is a life-threatening complication in monochorionic twin pregnancies caused by unbalanced placental blood flow. Definitive treatment requires endoscopic laser coagulation... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.