We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




First Electronic Wireless Implant Detects Early Signs of Transplanted Organ Rejection

By HospiMedica International staff writers
Posted on 08 Sep 2023

For individuals with transplanted kidneys, continuous monitoring of their organ's health is vital. More...

There is a possibility of organ rejection which can occur immediately post-transplant or years later, often without evident symptoms. Monitoring kidney health primarily involves tracking specific markers in the blood. Physicians rely on measurements of creatinine and blood urea nitrogen levels to gauge kidney function. However, fluctuations in these biomarkers, unrelated to rejection, can lead to inconclusive results, causing both false negatives and positives. The current gold standard for detecting rejection involves invasive biopsies, where physicians extract tissue samples from the transplanted organ, analyzing them for signs of impending rejection. Unfortunately, such procedures carry risks, including bleeding, infection, pain, and inadvertent damage to nearby tissues. Alternative blood biomarkers, when used alongside creatinine and blood urea nitrogen monitoring, have less than optimal predictive values.

Researchers at Northwestern University (Evanston, IL, USA) have developed the first electronic device for continuous, real-time monitoring of the health of transplanted organs. The sensor itself is remarkably compact, measuring just 0.3 centimeters in width, 0.7 centimeters in length, and 220 microns in thickness, making it smaller than a pinky fingernail and approximately the width of a single hair. To attach it to the kidney, the research team took advantage of the organ's natural biology. The kidney is enveloped by a protective fibrous layer called the renal capsule, and the sensor was designed to fit snugly beneath this layer, in direct contact with the kidney. This ultra-thin, soft implant can detect temperature irregularities associated with inflammation and other physiological responses linked to transplant rejection.

The device incorporates a highly sensitive thermometer capable of detecting minuscule temperature variations (0.004 degrees Celsius) specifically on the kidney. Although the sensor also measures blood flow, temperature emerged as a more reliable indicator of rejection. Elevated temperatures often accompany inflammation, leading the researchers to hypothesize that detecting abnormal temperature increases and variations could serve as an early warning sign of potential transplant rejection. These sensors connect to a compact electronics package, including a miniature coin cell battery for power, positioned adjacent to the kidney. Using Bluetooth technology, they continuously and wirelessly transmit data to external devices.

In a study, the device was tested on a small animal model with transplanted kidneys, and it proved capable of detecting early signs of rejection up to three weeks earlier than current monitoring methods. The researchers observed that the local temperature of the transplanted kidney increased, sometimes by as much as 0.6 degrees Celsius, before rejection events occurred. In animals not receiving immunosuppressant medications, temperatures increased two to three days before biomarkers in blood samples changed. In animals on immunosuppressant medications, temperature increases, along with additional variations, were noted as much as three weeks before creatinine and blood urea nitrogen levels rose. This extended lead time could allow physicians to intervene sooner, potentially improving patient outcomes, preserving donated organs, and addressing the growing demand for organs amidst a shortage crisis.

This innovative device not only detects rejection signs earlier than existing methods but also offers continuous, real-time monitoring. Following the success of the small animal trial, the researchers are now testing the system in a larger animal model. Additionally, they are exploring ways to recharge the coin cell battery for potential lifelong use. While initial studies focused on kidney transplants, the researchers believe this technology could extend to other organ transplants, including the liver and lungs, as well as other disease models.

“If rejection is detected early, physicians can deliver anti-rejection therapies to improve the patient’s health and prevent them from losing the donated organ,” said Northwestern’s John A. Rogers, a bioelectronics pioneer who led the device development. “In worst-case scenarios, if rejection is ignored, it could be life threatening. The earlier you can catch rejection and engage therapies, the better. We developed this device with that in mind.”

Related Links:
Northwestern University


Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Rapid Sepsis Test
SeptiCyte RAPID
Glucose Meter
StatStrip®
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: Masimo smartSET pulse oximetry with PPG AFib and OIRD Detection (Photo courtesy of Masimo)

Smart Pulse Oximetry Supports Earlier Recognition of Arrhythmias and Respiratory Risk

On general care floors, respiratory compromise and arrhythmias can develop between routine checks. Atrial fibrillation often goes undiagnosed in older adults, while opioid-induced respiratory depression... Read more

Patient Care

view channel
Image Credit: Adobe Stock

AI Platform Personalizes Support Between Visits for Cancer Survivors

Cancer survivors often manage persistent side effects after treatment, including fatigue, anxiety, uncertainty, symptoms, stress, and questions between appointments. Clinical teams need ways to maintain... Read more

Medical Imaging

view channel
Image: Brain PET imaging could help identify Alzheimer’s patients most likely to benefit from available therapies (Image Credit: iStock)

Amyloid and Tau PET Guide Selection and Monitoring of Alzheimer’s Therapy

Alzheimer’s disease is the most common form of dementia and can be difficult to distinguish from other causes of cognitive decline. According to the World Health Organization (WHO), 57 million people were... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: Steris is expanding its healthcare consumables portfolio through an agreement to acquire Xodus Medical, a surgical products business focused on patient and operating room staff safety.

Steris to Expand Surgical Safety Portfolio With $2.1 Billion Xodus Medical Deal

Steris has signed a definitive agreement to acquire Xodus Medical, a specialty surgical products business based in Pennsylvania, for $2.1 billion at closing. The acquisition will expand Steris’s healthcare... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.