A new study suggests that Polyglactin 910 (Vicryl) may be the optimal type of suture to use in the peritoneal cavity.

Researchers at Tokai University School of Medicine (Tokyo, Japan) conducted a study to explore the optimal suture materials for use in the peritoneal cavity, based on the formation of adhesions and abscesses under clean and contaminated conditions. More...
To do so, the researchers incised the parietal peritoneum and muscle layer of rats. The incision was followed by interrupted suturing in the clean group. A suspension of E. coli was sprayed onto the incision in the contaminated group, followed by interrupted suturing. Four types of sutures were used; nonabsorbable multifilament silk, absorbable multifilament Vicryl, absorbable monofilament Polydioxanone (PDS), and Poliglecaprone 25 (Monocryl).

The rats were sacrificed at 2, 4, or 8 weeks after the surgery. The researchers then examined the incidence of adhesions, and found it was low in the clean group with Polyglactin 910. The incidence of adhesions was 96 % or higher regardless of the suture type in the contaminated group. The incidence of severe adhesions was low with Polyglactin 910 and Poliglecaprone 25 and significantly higher with Polydioxanone in the contaminated group. The incidence of abscess formation around the silk was significantly higher than the other three types of sutures in the contaminated group. The study was published in the July 14, 2012, issue of Surgery Today.

“Polyglactin 910 was less likely to form adhesions than the other three types of sutures under both conditions, suggesting that Polyglactin 910 may be the optimal type of suture to use in the peritoneal cavity,” concluded lead author Kenji Ishikawa, PhD, and colleagues. “The reduction of the tensile strength with time did not differ significantly between sutures exposed to contaminated and clean conditions, even for the absorbable sutures.”

Vicryl is an absorbable, synthetic, braided suture, manufactured by Ethicon (Atlanta, GA, USA), a subsidiary of Johnson and Johnson (New Brunswick, NJ, USA). It is indicated for soft tissue approximation and ligation. The suture has a smooth, low friction proprietary coating that reduces tissue drag, and holds its tensile strength for approximately three to four weeks in tissue, completely absorbed by hydrolysis within 60 days.

Vicryl and other polyglycolic acid sutures may be treated to undergo more rapid breakdown in rapidly healing tissues such as mucous membrane, or impregnated with triclosan to provide antimicrobial protection of the suture line. Although the name Vicryl is a trademark of Ethicon, the term vicryl has been used generically referring to any synthetic absorbable suture made primarily of polyglycolic acid.

Related Links:

Tokai University School of Medicine
Ethicon
Johnson and Johnson



Gold Member
12-Channel ECG
CM1200B
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Resorbable Bovine Collagen Membrane
GenDerm
Tourniquet System
heidi– mein Tourniquet
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Clinical LLM Performance Improves by >300% When Provided with High-Quality Real-World Evidence in New Precision Medicine Benchmark (Photo courtesy of Atropos Health)

New Benchmark Highlights Evidence Gaps in AI Responses to Clinical Questions

Many clinical decisions still rely on limited evidence, while most artificial intelligence benchmarks overlook the patient context that shapes real-world care. General large language models can also struggle... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.