Thinner Minilaparoscopic Instruments Ease Procedural Tasks

By HospiMedica International staff writers
Posted on 21 Jan 2015
A new study that examined surgeons’ perceptions of transanal endoscopic microsurgery (TEM) using minilaparoscopic instruments reveals that thinner is better. More...


Researchers at the University of Sao Paulo (USP; Brazil), the Federal University of Pernambuco (Recife, Brazil), and other institutions hypothesized that visualization and maneuverability during TEM performed with 3-mm minilaparoscopic instruments would be superior to TEM performed with conventional 5-mm instruments. To test their hypothesis, 18 general and colorectal surgeons with minimal experience with TEM (i.e., under ten cases) were recruited to complete two tasks using a rectal simulator.

The first task was to use conventional 5-mm transanal endoscopic operation (TEO) curved-tip instruments to excise a 2-cm polypoid lesion, followed by closure of the rectal defect, all without previous instruction. In the second task, the same participants repeated the same excision and closure procedure, but this time using 3-mm mini-laparoscopic instruments. After completing both tasks, the participants filled an evaluation questionnaire containing seven questions regarding visualization and maneuverability, comparing the two sets of instruments on a scale of 1–5.

The results showed that for each one of the seven questions, all surgeons pointed out that their movements were more precise with 3-mm forceps, with 94.4% feeling more comfortable to complete the task. Only one surgeon claimed that the result was the same as he expected for conventional 5-mm forceps. All surgeons agreed that mini-laparoscopic instruments offered superior visualization for the proposed task. The study was published on January 8, 2014, in Surgical Endoscopy.

“Minilaparoscopic low-friction 3-mm instruments offered better visualization and were more reliable according to surgeons’ perception during task performance in a Neoderma TEO simulator,” concluded lead author Sergio Eduardo Alonso Araujo, PhD, of USP, and colleagues. “With mini-instruments it was easier and more comfortable to complete the procedure when compared with the conventional TEO instruments.”

The simulator used was a Neoderma trainer, which consists of a 30-cm long, 4-cm wide cylinder filled with neoderma, a synthetic material offering color, touch, consistency and texture similar to human tissues. The simulator is naturally self-expanded and closed at one end, simulating a gas-inflated rectum.

Related Links:

University of Sao Paulo
Federal University of Pernambuco



Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Surgical Dressing
ALLEVYN Ag+ SURGICAL
Desk Aneroid Sphyg
Diagnostix 750D+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Medical Imaging

view channel
Image: Raman spectroscopy showed that optical biomarkers associated with mature, functional elastic fibers were significantly reduced in the fibulin-5 deficient models. Histological staining (pictured here) confirmed substantial decrease in the amount of functional elastic fibers present within vaginal tissue. (Image Credit: Vanoven et al., doi 10.1117/1.BIOS.3.3.032106)

Noninvasive Optical Test Detects Hidden Tissue Damage in Pelvic Organ Prolapse

Pelvic organ prolapse (POP) occurs when weakened pelvic-support tissues allow the bladder, uterus, or rectum to descend. Although it affects millions of women, the condition remains under-characterized... Read more

Business

view channel
Image: The da Vinci SP system enables single-incision or natural-orifice procedures, enhancing visualization and precision in narrow or deep anatomical spaces (Photo courtesy of Intuitive)

Robotic Single-Port System Gains CE Mark for Transvaginal Gynecologic Procedures

Intuitive (Sunnyvale, CA, USA) announced that it has received CE mark approval for use of the da Vinci SP Single Port surgical system in transvaginal gynecologic procedures, marking the first such indication... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.