Simplified Bladder Measurement Identifies Postoperative Urinary Retention

By HospiMedica International staff writers
Posted on 17 Feb 2015
A simple ultrasound (US) test can accurately diagnose the common problem of postoperative urinary retention (POUR), according to a new study.

Researchers at Lapeyronie University Hospital (Montpelier, France) conducted a study to determine whether a simplified US measurement of just the largest transverse diameter of the bladder could be used to diagnose urinary retention. More...
One hundred patients at risk for POUR following orthopedic surgery were evaluated in the postanesthesia care unit before discharge. Bladder diameter was first measured using a portable ultrasound device; an automated evaluation of bladder volume was then performed. Finally, when bladder catheterization was performed, the actual urinary volume was measured (in 49 patients).

The researchers examined correlations between bladder volumes and diameter with receiver operating characteristic curves constructed to determine performance in predicting a bladder volume of over 600 mL. They found a significant correlation between the largest transverse diameter and urinary volumes, as assessed by the other two methods. The average bladder diameter was about 11 cm in patients with POUR, compared with 8–9 cm in those without POUR. The researchers determined that if the bladder diameter was 9.7 cm or less, the patient could be safely discharged.

If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The US test would be considered inconclusive only for patients in the "grey zone," i.e., between 9.7 and 10.7 cm. According to the researchers, the simplified measurement method could replace expensive bladder volume measuring devices or more complex US procedures involving the measurement of bladder diameters in three axial dimensions. The study was published on January 30, 2015, in Anesthesia & Analgesia.

“The findings of this study directly call into question the usefulness of expensive specific devices for assessing POUR in the postoperative period,” concluded lead author Aurélien Daurat, MD, and colleagues of the department of anesthesia and critical care medicine. “The test can be efficiently performed by nurses using a widely available portable ultrasound device, an important advantage over approaches using more complex measurements or specialized equipment.”

POUR is defined as the inability to void with a full bladder. The incidence of urinary retention after anesthesia and surgery ranges between 5% and 70%, depending on the type of surgery and the criteria used to define urinary retention. For the patient, retention of urine is painful and requires decompression of the urinary bladder using an intermittent or indwelling urethral catheter, although suprapubic catheterization may be considered if there is urethral trauma or stenosis. A problem arises, however, since catheterization is associated with risks, and an estimated 80% of hospital-acquired urinary tract infections are caused by indwelling urethral catheters.

Related Links:

Lapeyronie University Hospital



Gold Member
Blood Gas Analyzer
i-Check200
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Surgical Dressing
ALLEVYN Ag+ SURGICAL
Tourniquet System
heidi– mein Tourniquet
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Clinical LLM Performance Improves by >300% When Provided with High-Quality Real-World Evidence in New Precision Medicine Benchmark (Photo courtesy of Atropos Health)

New Benchmark Highlights Evidence Gaps in AI Responses to Clinical Questions

Many clinical decisions still rely on limited evidence, while most artificial intelligence benchmarks overlook the patient context that shapes real-world care. General large language models can also struggle... Read more

Critical Care

view channel
Image: Lead study author Ramy Ghanim (left) and co-author Joy Jackson test an small implantable device alongside Assistant Professor Alex Abramson. In a new Science paper, they describe a networking system that connects therapeutic implants and wearable devices by using the body’s natural conductivity to send tiny signals. (Photo courtest of Georgia Tech)

Bioelectronic Network Enables Devices to Communicate Through Body Tissue and Coordinate Therapy

Wearable sensors and implanted therapeutic devices can be difficult to coordinate when signals must pass through the body. Conventional wireless signals do not travel well through tissue, while the antennas... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.