We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
IBA-Radcal

Download Mobile App





Lung Ultrasound Scan Findings Can Help Identify False-Negative COVID-19 Test Results

By HospiMedica International staff writers
Posted on 10 Nov 2020
A new study has found that the integration of lung ultrasound (LUS) with clinical evaluation is associated with increased sensitivity for the diagnosis of COVID-19 pneumonia, and may facilitate the identification of false negative SARS-CoV-2 RT-PCR results.

Accurate diagnostic testing to identify SARS-CoV-2 infection is critical. More...
Although highly specific, SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR), has shown, in clinical practice, to be affected by a non-insignificant proportion of false negative results. For the study, the researchers enrolled consecutive adult patients with symptoms potentially related to SARS-CoV-2 infection admitted to the emergency department (ED) of an Italian academic hospital. Immediately after the initial assessment, a LUS evaluation was performed and the likelihood SARS-CoV-2 infection, based on both clinical and LUS findings (integrated assessment), was recorded. RT-PCR SARS-CoV-2 detection was subsequently performed.

The study enrolled 228 patients; 107 patients (46.9%) had SARS-CoV-2 infection. Sensitivity and negative predictive value of the clinical-LUS integrated assessment were higher than first RT-PCR [94.4% (95% CI 88.2-97.9), vs. 80.4% (95% CI 71.6-87.4); 95% (95% CI 89.5-98.2), vs. 85.2% (95% CI 78.3-90.6)]. Among the 142 patients who initially had negative RT-PCR, 21 resulted positive at a subsequent molecular test performed within 72 hours. All these false negative cases were correctly identified by the integrated assessment.

Based on the findings, the researchers have suggested that, in patients presenting to the ED with symptoms commonly associated with SARS-CoV-2 infection, the integration of LUS with clinical evaluation has high sensitivity and specificity for COVID-19 pneumonia and it may help to identify false negative results occurring with RT-PCR.



Gold Member
Blood Gas Analyzer
i-Check200
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Hypodermic Syringe
SurTract™ Safety Syringe
Blood Pressure Monitor
Cuff Blood Pressure Monitor
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: RADINA is an autonomous AI ecosystem designed to automate and coordinate imaging workflows throughout the patient journey (Photo courtesy of RADIN Health)

AI System Automates Radiology Workflows from Referral to Follow-Up

Imaging teams face ongoing staffing shortages, rising patient volumes, and growing administrative demands across referrals, authorizations, scheduling, reporting, and follow-up. Although existing software... Read more

Health IT

view channel
Image Credit: Shutterstock

Telemonitoring Program Improves Quality of Life After Heart Failure Discharge

Heart failure is a chronic condition associated with high mortality, frequent hospitalizations, and reduced quality of life. Patients face particularly high risks of readmission and death after discharge,... Read more

Point of Care

view channel
Image: Jessica Ramella-Roman, professor of biomedical engineering at Florida International University, holding the PPRIM (Portable Preterm Imaging) device designed to detect early signs of preterm labor risk. (Photo courtesy of Florida International University)

Handheld Imaging Device May Help Identify Preterm Birth Risk Earlier

Preterm birth, defined as delivery before 37 weeks of pregnancy, can lead to serious neonatal complications, including neurological, developmental, and respiratory problems. However, identifying pregnancies... Read more

Business

view channel
Image: Stryker has acquired ZuriMED, adding the FiberLocker System, a rotator cuff augmentation technology designed to strengthen repairs, to its Sports Medicine portfolio. (Photo courtesy of ZuriMED)

Stryker Completes Acquisition to Broaden Shoulder Surgery Offerings

Stryker (Portage, MI, USA) has completed its acquisition of ZuriMED (Zurich, Switzerland), a privately held developer of the FiberLocker System, expanding its Sports Medicine portfolio with a commercialized... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.