MRI and CT Predicts Flap Failure After Head and Neck Reconstructive Cancer Surgery

By HospiMedica International staff writers
Posted on 24 Jun 2022

When a patient with head and neck cancer has surgery to remove it, they often need reconstructive surgery in the form of a “free flap”, which is skin and tissue taken from a different part of the body and connected to the blood vessels of the wound in need of repair. More...

This free flap method, called microvascular reconstruction, carries around a 10-40% risk of wound complications, with 10% of cases requiring another surgery. Currently, most surgeons use ultrasound to assess viability for free flap reconstruction with techniques known as Doppler and skin paddle. Those methods often are unable to evaluate deeper aspects of the flap, or air and blood products cause interference in visualization, which affects how well clinicians can analyze a flap’s viability. Now, a study has found that early postoperative CT scans and MRIs can help predict whether a flap will fail, which could allow surgeons to intervene earlier.

In the study, a team of researchers from the University of Michigan Health (Ann Arbor, MI, USA) analyzed 19 patients who had successful free flap reconstruction, as well as five who had wound failure, between January 2016 to mid-2018. They found that both CT and MRI perfusion techniques showed significant differences between the two patient groups. Researchers were not able to compare the two methods to ultrasound techniques or each other due to the small sample size. They hope to accomplish those comparisons through a larger future trial.

“All patients who have this procedure can be investigated with non-invasive post-operative CT or MRI perfusion, and these two methods show a lot of promise as accurate biomarkers of predicting free flap viability,” said Ashok Srinivasan, M.D., FACR, a neuroradiologist at University of Michigan Health.

“This pilot research shows us that these models work, as all areas of the flap can be assessed using CT and MRI, unlike doppler and skin paddle where some areas may be blind to evaluation,” said Yoshiaki Ota, M.D., a neuroradiology fellow at University of Michigan Health. “We know that using CT and MRI could help shorten a patient’s hospital stay or avoid a prolonged hospitalization, and now we need to look further at which is more effective and cost-effective.”

Related Links:
University of Michigan Health 


Gold Member
Blood Gas Analyzer
i-Check200
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Multi-Chamber Washer-Disinfector
WD 390
Hypodermic Syringe
SurTract™ Safety Syringe
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Clinical LLM Performance Improves by >300% When Provided with High-Quality Real-World Evidence in New Precision Medicine Benchmark (Photo courtesy of Atropos Health)

New Benchmark Highlights Evidence Gaps in AI Responses to Clinical Questions

Many clinical decisions still rely on limited evidence, while most artificial intelligence benchmarks overlook the patient context that shapes real-world care. General large language models can also struggle... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.