Handheld Optical Coherence Tomography Imaging Device Developed for Primary Care Physicians

By HospiMedica International staff writers
Posted on 08 Oct 2012
A new handheld scanner for primary care physicians would enable them to image all the areas they typically study, such as bacterial colonies in the middle ear in three-dimensional (3D), or monitor the thickness and health of patients’ retinas, and more. More...


Surgeons in the operating room can visualize inside the human body in real time using sophisticated imaging technology, but primary care physicians have not typically had access to the same technology--until now. The device relies on optical coherence tomography (OCT), a visualization technology that is similar to ultrasound imaging, but uses light instead of sound to generate the images.

The engineers, from the University of Illinois at Urbana-Champaign (UIUC; USA), will present their findings at the Optical Society’s (OSA) annual meeting, Frontiers in Optics (FiO) 2012, taking place October 14-18, 2012, in Rochester, NY, USA.

To monitor chronic disorders such as ear infections, primary care physicians currently utilize instruments that are in essence magnifying glasses, according to UIUC physician and biomedical engineer Dr. Stephen Boppart, who will present the team’s findings at FiO. The new handheld imaging device would provide physicians with a way to quantitatively monitor these conditions, and possibly make more effective referrals to specialists.

The scanners include three basic parts: a near-infrared light source and OCT system, a video camera to relay real-time images of surface features and scan locations, and a microelectromechanical (MEMS)-based scanner to direct the light. Near-infrared wavelengths of light penetrate deeper into human tissues than other wavelengths more readily absorbed by the body. By gauging the time it takes the light to rebound back from tissue microstructure, computer algorithms construct an image of the structure of tissue under examination.

Diabetic patients should also benefit from the device. Approximately 40%-45% of diabetics develop retinopathy, which can lead to thickening of the retina, blurry vision, and eventually blindness. The handheld OCT device would allow doctors to monitor the health of the retina, potentially identifying retinopathy in its early stages. In some instances, changes in the eye could help clinicians diagnose diabetes, Dr. Boppart reported.

Dr. Boppart and his team are hopeful that decreased production costs combined with smaller, more compact designs will enable more physicians to take advantage of the scanners, and become a common point-of-care tool. Ultimately, they would like to see the imagers at work in developing countries as well. He and an international team of collaborators recently received a USD 5 million National Institutes of Health Bioengineering Research Partnership grant to further refine the device.

Related Links:
University of Illinois at Urbana-Champaign



Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
New
Gold Member
Neonatal Heel Incision Device
Tenderfoot
New
Fetal Monitor
BT-380
New
Hybrid Arch Device
Neo EDE
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: The approach pairs the ASI algorithm with the Acumen IQ finger cuff from Edwards Lifesciences to screen for clinically significant aortic stenosis (photo courtesy of Edwards Lifesciences)

Finger Cuff Algorithm Enables Noninvasive Screening for Aortic Stenosis

Aortic stenosis is a progressive narrowing of the aortic valve that can lead to heart failure and death if not treated in a timely manner. Symptoms such as fatigue, dyspnea, and dizziness often mimic normal... Read more

Surgical Techniques

view channel
Image: Six-month FlexPulse IDE data show positive outcomes with Abbott’s TactiFlex Duo catheter, confirming safety and efficacy seen in the CE Mark study for complex AFib (photo courtesy of Abbott)

Dual-Energy Ablation and Conduction System Pacing Show Positive Early Outcomes

Atrial fibrillation and other arrhythmias are common in both hospitalized and ambulatory patients, often complicating hemodynamic stability, stroke prevention, and perioperative care. Within this context,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.