Innovative Three-Step Ablation Strategy for Atrial Fibrillation Improves Patient Outcomes

By HospiMedica International staff writers
Posted on 19 Apr 2023

Total isolation of the pulmonary veins still remains the cornerstone of catheter ablation for atrial fibrillation. More...

However, only 50-60% of patients maintain sinus rhythm after two years. Various trials of alternative ablation strategies have not shown any superior results compared to pulmonary vein isolation (PVI). Now, a new study discovered that an innovative three-step ablation approach comprising ethanol infusion of the vein of Marshall provides greater freedom from arrhythmias in patients with persistent atrial fibrillation compared to PVI alone.

The Marshall-Plan ablation strategy involves: 1) PVI; 2) ethanol infusion of the vein of Marshall; and 3) a linear ablation set to block the three main anatomical isthmuses to the pulmonary veins (dome, mitral and cavotricuspid isthmus lines). This technique targets anatomical areas that are individually recognized as significant for initiating or maintaining atrial fibrillation, but have not been systematically addressed collectively. Investigators at University Hospital of Bordeaux (Bordeaux, France) had previously reported encouraging results from the use of this strategy in non-randomized studies. The current study compared the 12-month arrhythmia-free survival rate using the Marshall-Plan ablation strategy versus PVI only. This prospective, randomized, parallel group trial aimed to demonstrate superiority. The trial included 120 patients with symptomatic persistent atrial fibrillation lasting over a month. Participants had an average age of 67 years, with 21 (18%) being women.

Participants were randomly assigned to receive either the Marshall-Plan or PVI alone. They were followed up at 3, 6, 9, and 12 months, during which they underwent various tests including electrocardiograms (ECGs), echocardiography, stress tests, and 24-hour Holter monitoring. Recurrence of arrhythmias was detected using ECG teletransmission, with results sent to the hospital weekly and any time the patient experienced symptoms. The primary endpoint was the recurrence of atrial fibrillation or atrial tachycardia lasting over 30 seconds at 12 months (including a 3-month blanking period) after a single ablation procedure. Preliminary results at 10 months are presented, with follow-up ongoing until 12 months.

The total radiofrequency time was significantly longer in the PVI group (29 minutes) compared to the Marshall-Plan group (23 minutes; p<0.001). The complete lesion set was successfully achieved in 53 patients (88%) receiving the Marshall-Plan and 59 patients (98%) receiving PVI only. In an intention-to-treat analysis, arrhythmia recurrence after an average follow-up of 10 months was significantly higher in the PVI group compared to the Marshall-Plan group (18 vs. 8 patients; p=0.026).

“After 10 months of follow up, the success rate in the Marshall-Plan group was significantly better (87%) compared to the PVI only group (70%),” said principal investigator Dr. Nicolas Derval of the University Hospital of Bordeaux. “However, the results are still preliminary as follow up is not completed for all patients. While the findings indicate that the Marshall-Plan strategy holds promise for patients with persistent atrial fibrillation, they need to be confirmed in a multicentre trial.”

Related Links:
University Hospital of Bordeaux


Gold Member
Blood Gas Analyzer
i-Check200
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Tourniquet System
heidi– mein Tourniquet
Monitor/Defibrillator
Zenix
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image

Explainable AI Tool Improves Brain Disorder Screening from 4D fMRI

Functional magnetic resonance imaging (fMRI) captures changes in brain activity over time, but the resulting image sequences can be difficult to analyze. Screening for brain disorders requires assessing... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.