We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Simplified Atrial Fibrillation Ablation Technique Benefits Heart Failure Patients

By HospiMedica International staff writers
Posted on 05 Sep 2024

Atrial fibrillation (AF) impacts over 37 million individuals globally and frequently co-exists with heart failure, notably impairing the heart's capacity to pump blood effectively. More...

Particularly, heart failure with reduced ejection fraction (HFrEF) is identified when the left ventricular ejection fraction (LVEF) drops to 40% or below, affecting about 60% of heart failure patients. AF in heart failure patients is linked with higher risks of hospitalization, stroke, and mortality. Catheter ablation for AF, particularly using the prevalent radiofrequency (RF) method that employs heat to target heart tissue causing heart rhythm disturbance, is common but comes with significant risks and demands extensive training and procedural time.

Cryoballoon (CB) ablation, which uses cold temperatures to eliminate problematic heart tissue through a catheter, offers a simpler alternative. Yet, data comparing the efficacy of CB versus RF ablation in enhancing clinical outcomes, survival, and quality of life remains limited. Now, late-breaking research presented at ESC Congress 2024 shows that CB ablation matches the effectiveness of RF ablation in reducing AF and atrial tachycardia (AT) recurrence at one year in patients with HFrEF. Additionally, CB ablation offers the advantage of shorter procedure times and reduced fluid use during the procedure, potentially lowering the risk of worsening heart failure due to infusion overload during ablation.

The CRABL-HF trial conducted by the National Cerebral and Cardiovascular Center (Suita, Japan) involved 110 HFrEF and AF patients aged between 20-85 years across five Japanese sites, randomized to undergo either RF or CB ablation. The majority of participants were men, with a median age of 69. For those with cardiac implants, home monitoring tracked AF episodes, while others had twice-daily ambulatory ECGs for a year post-procedure after a 90-day blanking period. After one year, atrial tachyarrhythmias occurred similarly in both groups, with 21.8% in the RF group and 22.2% in the CB group experiencing episodes.

CB ablation not only required less time (median 101 versus 165 minutes) and fluid but also did not increase left atrium pulse pressure. Both procedures significantly improved left ventricular function and reduced left atrial volume index, enhancing cardiac function without notable safety differences between the groups. Each group experienced one procedural complication without causing exacerbation of heart failure or other severe outcomes. The one-year follow-up showed two deaths, one in each group, and hospitalizations due to heart failure were similarly rare and evenly distributed between groups. There was also no difference in the combined endpoint of death or heart failure hospitalization. Patient-reported quality of life, assessed by the Atrial Fibrillation Effect on Quality of Life questionnaire, improved significantly in both groups from baseline to one-year post-procedure.

“Our results show that CB ablation, a minimally invasive procedure that freezes out disruptive heart cells, is faster but as effective as the commonly used approach of burning the cells in order to put the heart back into a normal rhythm pattern,” said lead investigator Dr. Koji Miyamoto from the National Cerebral and Cardiovascular Center. “In addition, there was a very low risk of procedural complications in both groups, demonstrating that catheter ablation has become much safer over the years.”

Related Links:
National Cerebral and Cardiovascular Center


Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Medical-Grade Display
HL2316SHTB
Medical Adhesive
MED 5570U
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image

Explainable AI Tool Improves Brain Disorder Screening from 4D fMRI

Functional magnetic resonance imaging (fMRI) captures changes in brain activity over time, but the resulting image sequences can be difficult to analyze. Screening for brain disorders requires assessing... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.