We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




Expandable Stent Graft Treats Peripheral Artery Disease

By HospiMedica International staff writers
Posted on 14 Feb 2017
Print article
Image: The VIABAHN VBX balloon expandable endoprosthesis (Photo courtesy of Gore Medical).
Image: The VIABAHN VBX balloon expandable endoprosthesis (Photo courtesy of Gore Medical).
A novel balloon expandable stent graft aids treatment of de novo or restenotic lesions found in the iliac arteries, including lesions at the bifurcation.

The Viabahn VBX balloon expandable endoprosthesis consists of a 316L surgical grade stainless steel balloon expandable stent and a fluoropolymer graft with a proprietary heparin surface of porcine origin. The VBX is available in diameters ranging from 5 to 11 millimeters and lengths of 15, 19, 29, 39, 59, and 79 millimeters, as well as two shaft lengths, thus covering a wide variety of treatment needs up to 110 mm. In addition, it does not require pre-dilation, thus reducing the number of balloons required, contributing to procedural cost savings.

The VBX endoprosthesis is pre-mounted on a delivery system compatible with 0.035" guidewires, and is equipped with two radiopaque balloon markers embedded in the shaft to aid in correct placement. The delivery system can also be used for initial stent placement and post stent dilatation. The Viabahn VBX balloon expandable endoprosthesis is a product of Gore Medical Products, and has been approved by the U.S. Food and Drug Administration (FDA).

“The VBX Stent Graft combines radial strength with trackability and implanted conformability that results in successful outcomes for patients, providers, and physicians,” said Ray Swinney, peripheral interventional business leader at Gore. “There were no reported incidences of device dislodgement, failures in stent integrity, or device-related serious adverse events through the primary endpoint follow up, meaning no additional costs incurred for either endovascular or surgical stent removal.”

“The VBX Stent Graft demonstrated notable immediate and nine-month safety and efficacy in treating patients with iliac occlusive disease, which can be attributed to the exceptional device design,” said Jean Bismuth, MD, of Houston Methodist Hospital, who led the clinical study of the device. “Overall, there were multiple clinical benefits observed, including no median change in the device length upon deployment and a 100% technical success rate, with no occurrences of stent dislodgement or significant residual stenosis.”

PAD is a narrowing of the peripheral arteries due to atherosclerosis, and is most common in the arteries of the pelvis and legs. The most common symptoms of PAD are cramping, pain, or tiredness in the leg or hip muscles while walking or climbing stairs, which is temporarily relieved by rest. PAD sufferers have four to five times more risk of heart attack or stroke, and if left untreated, it can lead to gangrene and amputation.

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Surgical Table
STERIS 5085 SRT

Print article

Channels

Critical Care

view channel
Image: The stretchable microneedle electrode arrays (Photo courtesy of Zhao Research Group)

Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment

The field of personalized medicine is transforming rapidly, with advancements like wearable devices and home testing kits making it increasingly easy to monitor a wide range of health metrics, from heart... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.