Brain Mapping Tool Identifies Diseased Tissue

By HospiMedica International staff writers
Posted on 07 Jun 2017
Print article
Image: The PEDOT:PSS electrode grid (Photo courtesy of David Baillot / UCSD).
Image: The PEDOT:PSS electrode grid (Photo courtesy of David Baillot / UCSD).
A new device to map the brain during surgery provides higher resolution neural readings than existing tools used in the clinic and could enable doctors to perform safer, more precise brain surgeries.

Developed by researchers at the University of California, San Diego (UCSD, USA), Massachusetts General Hospital (MGH; Boston, USA), and other institutions, the device is an improved version of an electrocorticography electrode grid, which takes advantage of the electrochemical properties of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Using PEDOT:PSS allows the new electrode grid to be about a thousand times thinner than current clinical electrode grids.

The PEDOT:PSS microelectrode arrays is just 6 micrometers thick (versus several millimeters in current grids), which allows it to conform better to the intricately curved surface of the brain and obtain better readings. The new electrode grid also contains a much higher density of electrodes, since they can be spaced 25 times closer than those in current clinical electrode grids, enabling detection of changes in amplitude across pial surface distances as small as 400 µm, resulting in higher resolution recordings. The researchers also conducted several clinical tests.

In one test, the researchers performed background readings of a patient's brain waves both awake and unconscious. The PEDOT:PSS electrode grid identified normal functioning areas of the brain versus where the seizure areas with more detailed and higher resolution readings than the clinical electrode grid. Other tests that monitored the brain activity of patients performing cognitive tasks showed that both the PEDOT:PSS and standard electrode grids could differentiate between visual and audio inputs. The study was published on May 12, 2017, in Advanced Functional Materials.

“By providing higher resolution views of the human brain, this technology can improve clinical practices and could lead to high performance brain machine interfaces,” said senior author Professor Vikash Gilja, PhD, of the department of engineering at UC San Diego. “These electrodes occupy minuscule volumes; imagine Saran Wrap, but thinner. And we demonstrate that they can capture neural activity from the human brain at least as well as conventional electrodes that are orders of magnitude larger.”

Related Links:
University of California, San Diego
Massachusetts General Hospital

Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Baby Warmer
THERMOCARE Convenience

Print article

Channels

Critical Care

view channel
Image: The stretchable microneedle electrode arrays (Photo courtesy of Zhao Research Group)

Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment

The field of personalized medicine is transforming rapidly, with advancements like wearable devices and home testing kits making it increasingly easy to monitor a wide range of health metrics, from heart... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.