Tissue Reconnection Device Could Replace Surgical Stapling

By HospiMedica International staff writers
Posted on 23 Oct 2008
An innovative device reconnects tissues naturally after colorectal surgery, helping patients recover faster and experience fewer complications.

The NiTi Compression Anastomosis Ring reconnects tissue using a sophisticated ring made of nickel titanium (Nitinol, derived from its place of discovery, the U.S. More...
Nickel Titanium Naval Ordinance Laboratory), a strong but pliable metal alloy that has a "shape memory” effect. During placement, the elasticity of the Nitinol leaf springs enables the ring to adapt to differences in tissue thickness, uniformly bringing together tissues while applying consistent, controlled, circumferential pressure. The ring is placed using an applicator similar to that used with standard circular staples, but unlike stapling devices, the applicator is not withdrawn through the newly created reconnected tissue, eliminating the potential for trauma. After the ring is set, the process of the ring returning to its original closed position begins. The tissue trapped within the ring is cut off from blood supply and it becomes necrotic.

The first phase of wound healing--the lag or inflammatory phase--includes the critical task of phagocytosis or "cleaning” of the damaged, necrotic tissue of bacteria and other foreign cell matter. This lag phase is shorter with the NiTi compression anastomosis technology than with stapling because the extent of tissue trauma is minimal. Healing takes place by fibrous adhesion, without suppuration and formation of granulation tissue, a process called "healing by first intention.” The healing process results in the re-epithelialization and the full adaptation of the wall layers of anastomosed tissue, allowing a full recovery of the natural multilayer tissue lumen structure. The average time taken to reconnect tissue using the applicator is eight minutes. When the tissue connection is fully healed (usually within weeks), the ring passes out of the body, leaving behind healthy tissue that shows minimal signs of the surgery and leaving no foreign material in the body--unlike staples, which are left permanently behind. The NiTi Compression Anastomosis Ring is a product of NiTi Surgical Solutions (Netanya, Israel), and has been approved by the U.S. Food and Drug Administration (FDA).

"Our initial procedures prove that NiTi's reconnection device has the potential to replace the current standard of surgical stapling for closure following colorectal surgery,” said Stephen Cohen, a colorectal surgeon at Southern Regional Medical Center (Atlanta, GA, USA), who has used the compression ring in more than 40 procedures. "Our patients benefited immensely from this new technique, experienced minimal complications associated with traditional stapling methods, and recovered faster than patients with surgical staples. The NiTi compression ring is a true medical breakthrough that will allow surgeons to minimize discomfort for patients for many years to come.”

Related Links:
NiTi Surgical Solutions
Southern Regional Medical Center



Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
New
Medical-Grade Display
HL2316SHTB
New
POC Respiratory/Sore Throat Test
BIOFIRE SPOTFIRE (R/ST) Panel
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: Portable AI-powered scanning slit-light device brings low-cost eye screening closer to everyday life (	Kaushik, N., Sharma, P., Miya, T. et al. Scientific Reports, 2026. doi.org/10.1038/s41598-026-44392-w)

Portable AI Device Enables Low-Cost Screening for Anterior Eye Diseases

Anterior-segment eye diseases, including cataract, keratoconus, and angle‑closure glaucoma risk, are major drivers of preventable vision loss. Angle‑closure events can cause sudden, profound loss of sight,... Read more

Health IT

view channel
Photo courtesy of Adobe Stock

Automated System Classifies and Tracks Cardiogenic Shock Across Hospital Settings

Cardiogenic shock remains a difficult, time-sensitive emergency, with delayed identification driving poor outcomes and persistently high mortality. Many cases go undocumented even at advanced stages, hindering... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.